Skip to content
Home/ Delivered Systems/GSK-Q-700
GSK-Q-700

GSK-Q-700 high-precision heat treatment furnace

Annealing & heat treatment ≤ 700 °C Inert / reducingAmbient air Annealing
KEY DATADELIVERED
MAX TEMP
700℃
ATMOSPHERE
Inert / reducing / Ambient air
CATEGORY
Annealing & heat treatment
SOURCE
Proposal text
From the original technical proposalAHGSTEC
Specification

Specification

Taken from the original technical proposal. Ranges indicate configurable options; the signed technical agreement governs.

Primary A

Temperature accuracy
±1 °C
Control system / instrument class / program
Thermocouple: K-type
Thermocouple / compensating cable
K-type
Model
GSK-Q-700

Secondary B

Typical operating temperature
700℃
Continuous operating temperature
≤600℃
Total power
18 kW, three-phase 380 V, five-wire
Rack
One fixed rack per furnace, 6 layers at 65 mm pitch
Structure

Cross-section

Click any part to see its role. Together these eight determine the final thermal performance.

CHAMBER INSULATION INSULATION AIR DUCT DOOR LOCK TC PORT CONTROL HEATING HEATING
PART 01

Chamber

One-piece polycrystalline alumina ceramic fiber. High density, low conductivity, no dusting at temperature — the first determinant of uniformity.

Material
Polycrystalline alumina fiber
Continuous rating
≤ 650 °C
Construction
Seamless, one-piece