High-temperature environment test platform for strain gauges
Lab & testing ≤ 1700 °C Ambient air Testing
KEY DATADELIVERED
MAX TEMP
1700℃
ATMOSPHERE
Ambient air
CATEGORY
Lab & testing
SOURCE
Proposal text
From the original technical proposalAHGSTEC
Specification
Specification
Taken from the original technical proposal. Ranges indicate configurable options; the signed technical agreement governs.
Primary A
- Heating elements
- U-shaped MoSi₂ elements, max operating temperature 1700 °C
- Operating temperature
- -200~1600℃
Secondary B
- Achieved accuracy
- Closed-loop linear encoder control; repeat positioning accuracy ±3 µm (requirement 10 µm)
Structure
Cross-section
Click any part to see its role. Together these eight determine the final thermal performance.
PART 01
Chamber
One-piece polycrystalline alumina ceramic fiber. High density, low conductivity, no dusting at temperature — the first determinant of uniformity.
- Material
- Polycrystalline alumina fiber
- Continuous rating
- ≤ 650 °C
- Construction
- Seamless, one-piece
Related
Related systems
Integrated uniform-temperature heating stage
TEMP700 °C
ATMOSPHEREAmbient air
PROCESSAnnealing
CATEGORYLab & testing
DH-3S-D
DH-3S-D ignition point test muffle furnace
TEMP900 °C
ATMOSPHEREAmbient air
PROCESSTesting
CATEGORYLab & testing
GST-3212H
GST-3212H high-temperature fire simulation test chamber
TEMP1200 °C
ATMOSPHEREAmbient air
PROCESSTesting
CATEGORYLab & testing