From the original technical proposalAHGSTEC
Specification
Specification
Taken from the original technical proposal. Ranges indicate configurable options; the signed technical agreement governs.
Primary A
- Model
- GS-T-1100S
- Max. service temperature
- 1100 °C
- Working temperature range
- 800–1100 °C (calibrated over the full range)
- Uniform-temperature zone
- 250 × 200 × 150 mm (D×W×H)
- Minimum uniform-temperature zone
- 200 × 200 × 150 mm
- Uniform-zone temperature accuracy
- ±5 °C (full temperature range)
- System accuracy test (SAT)
- ≤±1.1 °C
- Control accuracy
- ±1 °C
- Temperature uniformity
- ±5 °C
- Control mode
- PID auto-tuning + SSR solid-state relay output
- Temperature monitoring
- Five-thermocouple system: control, recording, monitoring, load and SAT thermocouples
Secondary B
- Chamber dimensions
- 300 × 250 × 200 mm (D×W×H)
- Chamber material
- Alumina ceramic fibre
- Shell material
- Cold-rolled steel sheet + electrostatic spray coating
- External body temperature
- ≤50 °C
- Overall dimensions (approx.)
- 850 × 750 × 1200 mm (D×W×H)
- Control cabinet dimensions
- 600 × 500 × 1200 mm (D×W×H)
- Supply voltage
- AC 380 V ±10 %, 50 Hz, three-phase five-wire
- Rated power
- approx. 12–15 kW
- Max. operating current
- approx. 23 A (calculated at 15 kW)
- Safety protection
- Over-temperature protection (independent monitoring thermocouple + over-temperature alarm controller, dual protection); door interlock cutting heater power on opening; over-current / short-circuit protection via circuit breakers on each loop; earthing protection; audible and visual alarm
- Installation conditions
- Indoor level floor, good ventilation; ambient temperature 5–40 °C; relative humidity ≤85 % (non-condensing); no strong electromagnetic interference sources or corrosive gases nearby
Structure
Cross-section
Click any part to see its role. Together these eight determine the final thermal performance.
PART 01
Chamber
One-piece polycrystalline alumina ceramic fiber. High density, low conductivity, no dusting at temperature — the first determinant of uniformity.
- Material
- Polycrystalline alumina fiber
- Continuous rating
- ≤ 650 °C
- Construction
- Seamless, one-piece
Related
Related systems
GSK-40-700Y
GSK-40-700Y precision annealing furnace for molded aspheric optical glass lenses
TEMP700 °C
ATMOSPHEREAmbient air
PROCESSAnnealing
CATEGORYAnnealing & heat treatment
GSK-Q-700
GSK-Q-700 high-precision heat treatment furnace
TEMP700 °C
ATMOSPHEREInert / reducing / Ambient air
PROCESSAnnealing
CATEGORYAnnealing & heat treatment
GSK-80-750
GSK-80-750 precision annealing furnace
TEMP700 °C
ATMOSPHEREAmbient air
PROCESSAnnealing
CATEGORYAnnealing & heat treatment