Skip to content
Home/ Delivered Systems/GS-T-1100S
GS-T-1100S

GS-T-1100S high-temperature heat treatment furnace

Annealing & heat treatment ≤ 1100 °C Ambient air Annealing
KEY DATADELIVERED
MAX TEMP
1100
ATMOSPHERE
Ambient air
CATEGORY
Annealing & heat treatment
SOURCE
Proposal text
From the original technical proposalAHGSTEC
Specification

Specification

Taken from the original technical proposal. Ranges indicate configurable options; the signed technical agreement governs.

Primary A

Model
GS-T-1100S
Max. service temperature
1100 °C
Working temperature range
800–1100 °C (calibrated over the full range)
Uniform-temperature zone
250 × 200 × 150 mm (D×W×H)
Minimum uniform-temperature zone
200 × 200 × 150 mm
Uniform-zone temperature accuracy
±5 °C (full temperature range)
System accuracy test (SAT)
≤±1.1 °C
Control accuracy
±1 °C
Temperature uniformity
±5 °C
Control mode
PID auto-tuning + SSR solid-state relay output
Temperature monitoring
Five-thermocouple system: control, recording, monitoring, load and SAT thermocouples

Secondary B

Chamber dimensions
300 × 250 × 200 mm (D×W×H)
Chamber material
Alumina ceramic fibre
Shell material
Cold-rolled steel sheet + electrostatic spray coating
External body temperature
≤50 °C
Overall dimensions (approx.)
850 × 750 × 1200 mm (D×W×H)
Control cabinet dimensions
600 × 500 × 1200 mm (D×W×H)
Supply voltage
AC 380 V ±10 %, 50 Hz, three-phase five-wire
Rated power
approx. 12–15 kW
Max. operating current
approx. 23 A (calculated at 15 kW)
Safety protection
Over-temperature protection (independent monitoring thermocouple + over-temperature alarm controller, dual protection); door interlock cutting heater power on opening; over-current / short-circuit protection via circuit breakers on each loop; earthing protection; audible and visual alarm
Installation conditions
Indoor level floor, good ventilation; ambient temperature 5–40 °C; relative humidity ≤85 % (non-condensing); no strong electromagnetic interference sources or corrosive gases nearby
Structure

Cross-section

Click any part to see its role. Together these eight determine the final thermal performance.

CHAMBER INSULATION INSULATION AIR DUCT DOOR LOCK TC PORT CONTROL HEATING HEATING
PART 01

Chamber

One-piece polycrystalline alumina ceramic fiber. High density, low conductivity, no dusting at temperature — the first determinant of uniformity.

Material
Polycrystalline alumina fiber
Continuous rating
≤ 650 °C
Construction
Seamless, one-piece